POWER PROBE

Introduction

The Power Probe Professional Electrical Test Kit provides the circuit testing ability of the Power Probe 3 combined with the diagnostic capabilities of the Power Probe Digital Multimeter.

Introduction

The Power Probe Professional Electrical Test Kit provides the circuit testing ability of the Power Probe 3 combined with the diagnostic capabilities of the Power Probe Digital Multimeter.

Features

PP3

-

DC Voltmeter Indicators provide active feedback

-

LED Lights

-

Bad Ground Indicator

-

Short Circuit Indicator

-

Relay and Component Tester

-

Audible Monitoring of Electrical Signals

 

DMM

-

CAT-IV 600V hybrid safe rating

-

Digital Volt and Ohmmeter for circuit testing

-

Measures Frequency for Sensor Testing

-

Included K-Type Temp Probe allows for temperature readings

Features

PP3

-

DC Voltmeter Indicators provide active feedback

-

LED Lights

-

Bad Ground Indicator

-

Short Circuit Indicator

-

Relay and Component Tester

-

Audible Monitoring of Electrical Signals

 

DMM

-

CAT-IV 600V hybrid safe rating

-

Digital Volt and Ohmmeter for circuit testing

-

Measures Frequency for Sensor Testing

-

Included K-Type Temp Probe allows for temperature readings

PP3

- DC 0 – 70V + 1 digit

- P-P 0 – 70V

Frequency response of tone pass through

- 10Hz to greater than 10 Khz

PP display

- 15Hz Square Wave

- 35Hz Sine Wave

Power Probe Mode – Continuity to ground

- First level – display is enabled less than 20K

- Second level – green LED is enabled less than 2K

– & + Peak Detector Response

- Single event capture less than 200μs pulse width

- Repetitive events less than 1μs pulse width

Peak to Peak Mode

- 0 – 70V + 1 digit

- 4Hz to over 500kHz Square Wave input

- 4Hz to over 250kHz Sine Wave input

Threshold for PPAC/Audible passthrough

Circuit Breaker

8 amp thermal response – Manual reset

Typical Response

 

DMM

Operating Altitude

2000m

Relative Humidity

75% max operating

Operating Temperature

0°C~40°C/32°F~104°F (<80% RH)

Storage Temperature

-10°C~60°C/14°F~140°F (<70% RH)

Accuracy Temperature

-18°C~28°C/64°F~82°F (<80% RH)

Temperature Coefficient

0.1x(specified accuracy)/°C (<18°C or >28°C)

Sampling Frequency

approx. 3 times/sec.

Fuse Protection

μA/mA input: F600mA/600V 10A input: F10A/600V

DC/AC Voltage

600V

DC/AC Current

10A

Resistance

60MΩ

Capacitance

60mF

Frequency

10kHz

Diodes

2.7V

Continuity

<50Ω

Temperature

-20°C~1000°C/-4°F~1832°F

LCD Display

3 ¾ digit display (6000 counts)

Product Supply

3x1.5V AAA batteries

Product Size

160mmx74mmx49mm / 6.3"x2.9"x1.9"

Product Weight

482g / 1.06lb

Safety Rating

CAT IV 600V

Safety Standards

IEC61010-1

Pollution Degree

2

Accuracy

±(of reading + # of least significant digits)